Skip to main content
Electric All Pro Electrician
Dedicated Circuit Installation

Dedicated Circuit Installation in Raleigh, NC

New 120-volt and 240-volt circuits run from your panel to the appliance that needs one, in the kitchen, garage, laundry, home office or shop.

Last Updated: November 2026
Its Own BreakerOne appliance per circuit
120 V & 240 V20 A to 50 A circuits
Labeled & TestedBreaker marked in the panel
Labeled dedicated 20-amp outlet installed in a basement with an appliance plugged in
A Circuit of Its OwnNo sharing, no nuisance trips.
NC Licensed L.32531Electrical Contractor
$1M / $2M CoverageGeneral Liability Insurance
5.0 RatingGoogle Reviews
Since 20186,000+ Jobs Completed
Safety-Driven Electrical Service

Dedicated Circuit Installation Overview

A dedicated circuit is a breaker and a wire run that feed one appliance and nothing else, so a freezer, a microwave or a space heater never shares its power with the rest of the room. We add 120-volt, 20-amp circuits for kitchens, garages, laundries, home offices and appliances, and 240-volt circuits for dryers, ranges, mini-splits and shop equipment, from a new breaker in your panel to a labeled outlet or disconnect where you need it.

  • One Appliance, One Breaker

    No more trips when the microwave and the toaster run at the same time.

  • 120 V and 240 V

    20-amp circuits for appliances and outlets; 30- to 50-amp circuits for dryers, ranges and equipment.

  • Load Checked First

    We confirm your panel has the room and the capacity before we add anything.

When To Schedule a Dedicated Circuit

A shared circuit trips when too much runs on it at once. Book a dedicated circuit when any of these apply:

New Appliance Coming? Book the circuit before the appliance is delivered.
1
Visit · Most Single Circuits Installed in One Visit
Signs You Need a Dedicated Circuit
  • A breaker trips when the microwave, kettle or space heater runs
  • A new freezer, refrigerator or wine cooler going into the garage
  • A dryer, range or cooktop that needs a 240-volt outlet
  • A mini-split, window AC or shop tool that calls for its own circuit
  • A home office with computers and printers on a shared circuit
  • An extension cord running to an appliance with no outlet near it

Common Reasons Homeowners Book This Service

Kitchen and microwave circuits, garage freezer and refrigerator circuits, home office circuits, and 240-volt circuits for dryers, ranges, mini-splits and equipment.

Cost Overview

Dedicated Circuit Pricing Guidance

Dedicated circuit work in Raleigh, NC is priced on site after a free estimate. These are the factors that move the price.

Typical Price Range
Free Estimate
  • Every new circuit is priced on site after a free estimate, with the price in writing before any work
  • Regular services have a $180 minimum; a sub-panel or panel upgrade is quoted separately
  • Distance From the PanelA circuit to the other side of the wall is quick; a run to a detached garage or across the house takes longer.
  • 120 V or 240 VA 20-amp appliance circuit uses lighter wire than a 50-amp range or equipment circuit.
  • Room in the PanelA full panel may need a sub-panel or an upgrade first, which is quoted separately.
Service Details

What’s Included / What’s Not

Here’s exactly what our standard dedicated circuit installation includes, and what falls outside it.

Included

New BreakerA breaker sized to the appliance, in an open space in your panel.
Wire RunWire sized to the breaker, run from the panel to the appliance location.
Outlet or DisconnectThe right receptacle, or a disconnect where the appliance needs one, mounted and labeled.
Test and LabelThe circuit tested under load and the new breaker labeled in the panel.

Not Included

The ApplianceYou buy the appliance; we wire the circuit it runs on.
Gas, Water and VentingPlumbing, gas lines and ducts for the appliance are other trades.
Drywall and PaintPatching around new openings is a separate trade.
A Full PanelWhen the panel has no room, a sub-panel or upgrade is quoted separately.
Service Process

How a Dedicated Circuit Gets Installed Properly

Every dedicated circuit in Raleigh, NC starts at the panel: is there an open space, and is there capacity for the new load?

Sized to the ApplianceThe breaker, the wire and the outlet are matched to the nameplate of what you plug in.

  1. 1

    Check the Panel and the Load

    We read the appliance's nameplate, confirm the panel has an open space and enough capacity, and plan the shortest clean route for the wire.

    Capacity checked Route planned
  2. 2

    Run the New Circuit

    A new breaker, wire sized to it, and the right outlet or disconnect at the appliance, with GFCI or AFCI protection wherever code calls for it.

    Wire sized to breaker GFCI or AFCI as required
  3. 3

    Test and Label

    The circuit is tested under load, the outlet is checked for correct wiring, and the new breaker is labeled in the panel.

    Tested under load Breaker labeled

Tired of Resetting the Same Breaker?

Most single circuits are installed in one visit.

Real Home Gains

Benefits of a Dedicated Circuit

A dedicated circuit in Raleigh, NC gives a hard-working appliance its own power and keeps the rest of the house from tripping with it.

Electrical panel with a labeled breaker for each appliance circuit and an Electric All Pro sticker
One BreakerPer Appliance
No More OverloadsThe microwave, kettle and toaster stop fighting over one 20-amp circuit.
Appliances Run RightMotors and compressors get full voltage instead of dimming the lights when they start.
Easy to FindEach new breaker is labeled, so you know exactly what it controls.
Homeowner Reviews

What Homeowners Say In Recent Reviews Online

Recent reviews from our Google Business Profile. They cover our work across the Triangle rather than this service alone — every card links to the original on Google.

“Great explanation and service. If needed will not hesitate to use again. Thank you for everything ❤️”

Melanie Baiardo, Google reviewer Melanie Baiardo read it on Google

“Electric All Pro is a fantastic company. Responsive. Knowledge. Great customer service. Not only did they help me better understand the issue I was…”

Jim Ferguson, Google reviewer Jim Ferguson read it on Google

“Had a lot of outlets go out needed them repaired to be able to work the next day. Due to there emergency service and being a 24 he electrician. They…”

Connor Rice, Google reviewer Connor Rice read it on Google

Rated 5.0 out of 5 based on 180+ Google reviews

Read more reviews on Google
Service Options

Optional Add-Ons for Dedicated Circuits

These add-ons are commonly paired with a new circuit in Raleigh, NC homes.

GFCI and USB Outlets

GFCI protection or USB charging outlets on the new circuit where they make sense.

Whole-House Surge Protection

Protect the new appliance and everything else in the house at the panel.

Sub-Panel for More Circuits

When the main panel is full, a sub-panel adds room for the circuits you need.

Electrical Standards

Dedicated Circuit NEC Code Requirements

New circuits in North Carolina homes follow the National Electrical Code as the state adopts it, and every one is sized to the load it serves.

NEC 210.11(C)

1. Kitchen and Laundry Circuits

Kitchens need at least two 20-amp small-appliance circuits, and the laundry needs a 20-amp circuit of its own.

NEC Ref: 210.11(C)

Two or more 20-ampere small-appliance branch circuits shall be provided for the kitchen, pantry, breakfast room and dining room receptacles, and at least one 20-ampere branch circuit shall supply the laundry receptacle outlets.

NEC 210.11(C)(4)

2. Garage Circuits

An attached garage, or a detached garage with power, gets at least one 20-amp, 120-volt circuit for its outlets.

NEC Ref: 210.11(C)(4)

At least one 120-volt, 20-ampere branch circuit shall be installed to supply receptacle outlets in attached garages and in detached garages with electric power.

NEC 240.4(D)

3. Wire Sized to the Breaker

The wire must be rated for the breaker that protects it: 12 AWG copper on 20 amps, 10 AWG on 30 amps.

NEC Ref: 240.4(D)

Small conductors shall not be protected at more than 15 amperes for 14 AWG, 20 amperes for 12 AWG and 30 amperes for 10 AWG copper.

NEC 210.8 / 210.12

4. GFCI and AFCI Protection

New circuits in kitchens, laundries, garages, basements and outdoors get GFCI protection; bedrooms and living areas get AFCI.

NEC Ref: 210.8 / 210.12

GFCI protection for personnel is required in specified dwelling locations, and AFCI protection for 120-volt branch circuits supplying most living areas.

Local Coverage

Proudly Serving Raleigh, NC & The Surrounding Triangle

Electric All Pro provides professional dedicated circuit installation services throughout Raleigh, NC and the surrounding Triangle. Select your city below to confirm we service your area.

Map of Electric All Pro service coverage across Raleigh and nearby Triangle communities

Not sure if we service your area?

Our team covers most of Wake, Durham, and Johnston counties.

Check My Address
Request a Free Estimate

Ready to Stop Sharing Circuits?

Get a fast, no-obligation estimate from a licensed Raleigh electrician. We’ll review your project and help you choose the right solution.

Licensed NC Contractor No Obligation Fast Response
Frequently Asked Questions

Common Questions

Common questions from Raleigh homeowners about dedicated circuits.

Still have questions?

Our Raleigh electrical experts are here to help you every step of the way.

Real People. Real Answers.
We're here when you need us.
How much does a dedicated circuit cost in Raleigh?

It depends on the distance from the panel, the size of the circuit and the room in your panel, so we price each one on site after a free estimate, in writing before any work. Regular services have a $180 minimum.

Which appliances need a dedicated circuit?

Microwaves, dishwashers, disposals, refrigerators and freezers, dryers, ranges and cooktops, water heaters, mini-splits and most shop equipment. The appliance's installation guide says which circuit it needs.

What is the difference between a 120-volt and a 240-volt circuit?

A 120-volt, 20-amp circuit feeds standard outlets and most kitchen appliances. A 240-volt circuit, usually 30 to 50 amps, feeds dryers, ranges, mini-splits, welders and EV chargers.

Is my panel big enough for another circuit?

We check both the open spaces and the load before we quote. If the panel is full or near its limit, we explain the options: a sub-panel, load management or a panel upgrade.

Do I need a permit for a new circuit?

When the work needs a permit, we pull it and schedule the inspection, so you do not have to deal with the city or county yourself.

Can you add a circuit for an EV charger or a hot tub?

Yes. Those circuits have their own pages and their own prices: see our EV charger installation and hot tub wiring services.

Call (919) 670-4005 Book Online